. Contents page CAUTION Check List / Shop@Panasonic Front Panel Rear Panel / Inserting batteries Remote control functions Connections without Scart cable 10-11 with Scart cables and Satellite Receiver 12-13 Video Cassette Recorder with Scart cables 14-15 AUTO SETUP 16-17 NV-MV20EB/EBL.
- Jan 18, 2017 - I have read numerous posts on the EBL99 problems & sometimes it. I downloaded a 2011 Burstner I Model instruction manual from the.
- PDF manuals are eady to download and. The service manual describes. ELEKTROMATIC LA110 ANL SCHAUDT EBL 99 G SCHEMI ANLEIT SCHAUDT EBL 99 G SCHEMI.
PDF manuals are eady to download. The service manual describes. ELEKTROMATIC LA110 ANL SCHAUDT EBL 99 G SCHEMI ANLEIT SCHAUDT EBL 99 G SCHEMI. Dec 22, 2017 - User Manual SCHAUDT Electrobloc EBL 99 G - This User Manual - also. We provide PDF manuals: easy to download, the documents can be. Bokepdo.club Movie Korea. User Manual SCHAUDT Electrobloc EBL 99 G - This User Manual - also called owner's manual or operating instructions - contains all information for the user to make full use of the product. This manual includes a description of the functions and capabilities and presents instructions as step-by-step procedures. Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP 811.419 BA / EN Date: 3 2 Introduction Y This device is intended solely for use in vehicles. This instruction manual contains important information for safe operation of the device. Ensure you read and follow the safety instructions provided.
Elektroblock EBL 4, EBL 29, EBL 99, EBL 100, EBL 101, EBL 104, EBL 105, EBL 108. EBL 119 Instructions manual in English. 1 million PDF manuals for immediate download (user manual. Schaudt units are reliable.
Caution Be sure to read the cautions carefully before you operate this VCR. Keep the VCR away from high temperatures Keep the VCR away from sources of heat such as direct sunlight, heating radiators, or closed vehicles. Avoid magnets or magnetized objects Never bring a magnet or magnetized object close to the VCR because this could adversely affect the performance of the VCR.
Avoid humidity and dust Do not use the VCR in very humid or dusty places. This may cause damage to its internal parts.
Stacking Install the VCR in a horizontal position and do not place anything heavy on it. Condensation may form in the following cases: If the VCR is in a room that was very cold before a heater has just been turned on. CAUTION Caution for AC Mains Lead For your safety, please read the following text carefully.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 5-ampere fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5-ampere and that is approved by ASTA or BSI to BS1362. Or go on line through our Internet Accessory ordering application. Most major credit and debit cards accepted.
All enquiries transactions and distribution facilities are provided directly by Panasonic UK Ltd. It couldn't be simpler! Customer Care Centre. Front Panel EJECT 60SEC. JET REWIND EXTERNAL LINK INTELLIGENT TIMER PROG PLAY TIMER REC NV-MV20 QUICK ERASE EXT LINK TIMER CHECK 9 10 11 12 13 Stand-by/on switch /I Defines timer programmes. INTELLIGENT TIMER Plays back programmed recordings. PROG PLAY EJECT Ejects the cassette.
Rear Panel AV1 (TV) AC IN SECTEUR OUT/ SORTIE AC Input socket ( Power supply) AV1 21-pin Scart socket RF IN socket (Aerial input) RF OUT socket (Aerial output) Inserting batteries into the remote control unit: The batteries last for about a year, depending on how often you use the RC unit. Do not mix old with new batteries or batteries of different types. Remote control functions Some Panasonic TV sets accept control signals from the VCR's remote control unit. In the table, the TV buttons are marked with, the VCR buttons with Stand-by/on switch Press to switch the unit from on to stand-by mode or vice versa. In stand-by mode, the unit is still consuming a small amount of power.
VIDEO Plus+ Displays the VIDEO Plus+ menu. 30 Selects a programme memory location and inputs the VIDEO Plus+ number.
PROG PLAY Plays back programmed recordings. Example: 18= P. 24 Selects the TV set's AV port. INPUT SELECT Toggles between AV input and TV station. Connections You can connect your VCR to a TV and Satellite Receiver using RF cable. Without Scart cable However, using this connection method it may be difficult to obtain a clear picture from the Satellite Receiver. For this reason it is not recommended for inexperienced users.
(See preferred connection on page 12.) Aerial Input socket Satellite Receiver. Follow the step-by-step guide below.
Connect the aerial to the aerial input socket of the Satellite Receiver. Satellite Receiver - If you do not have a Satellite Receiver, connect the aerial to the RF input socket of the VCR and go to step. 3 Satellite Receiver Connect the aerial from Satellite Receiver to the RF Input socket.
Connections with Scart cables and Satellite Receiver RF Input socket (fully-wired) RF Output socket AV1 21-pin Scart socket AC Input socket Aerial AC Mains lead (supplied) RF cable (supplied) Necessary for Connecting a Satellite Receiver 21-pin Scart socket (VCR) Aerial Input socket Satellite Receiver 21-pin Scart socket (TV) To AC Mains socket. Follow the step-by-step guide below. Connect the aerial to the RF Input socket of the VCR.
SORTIE Connect the RF cable from the RF Output socket of the VCR to the TV aerial input socket. SORTIE AV1 ( TV ) Connect the AV1 21-pin scart socket to the VCR scart socket on your Satellite Receiver/Digital Receiver. Connections with Scart cables (fully-wired) RF Input socket RF Output socket AV1 21-pin Scart socket AC Input socket Aerial AC Mains lead RF cable (supplied) (supplied) Aerial Input socket Necessary for TV AV1 socket To AC Mains socket. Follow the step-by-step guide below.
Connect the aerial to the RF Input socket of the VCR. SORTIE Connect the RF cable from the RF Output socket of the VCR to the TV aerial input socket. SORTIE Connect the AV1 21-pin scart socket to the TV scart AV1 ( TV ) socket. AUTO SETUP Set the VCR/TV switch to VCR. Turn on the TV, then press the VCR-Stand-by/ON button to switch on the VCR. The VCR will now start Auto Setup.
While Auto Setup is running the first digit of the VCR display will flash. After a while it will stop flashing and the RF output channel number will be displayed. If the clock setting menu appears Datum / Zeit Clock set (Auto clock set was not possible due to a weak signal) MANUAL! Press to set the correct time and date. Time: 12: 00: 00! Press the Date: 11.
Checking the Settings To confirm that the TV stations have been tuned correctly by Auto Setup for Auto Setup MENU Press the MENU button to display the OSD Main menu on the TV screen. On Screen Display Press to select Tuning then press the ENTER button. Removing Interference / Changing RF-channel In some cases, interference (lines or patterning) or a very poor picture may appear on the TV when the VCR is connected. If this happens, follow the steps below to change the video playback channel (RF output channel) to remove the interference. Menu System Timer recording 1 / 3 Page 27 Date Start Stop - - - / - -:- -:- - - - / - -:- -:- - - - / - -:- -:- - - - / - -:- -:- - - - / - -:-. Menu Overview The cursor keys of the remote control unit allow you to move between Menu menus and to change settings.
Timer recording Tuning Clock set Press MENU to display the Menu screen. Others Select an entry by pressing ENTER to access the selected sub-menu. Playback Set the TV set to the video channel and insert a cassette into the VCR Normal Playback: Press. Cue or Review Playback: During playback, press and release. To return to normal playback, press. If you pre ss and hold down the, Cue or review playback continues for as long as you kee p the button pressed. Tracking control Adjusting the playback picture Under normal conditions, the VCR automatically adjusts the tracking for optimum performance.
However, in some cases it may be necessary to adjust it manually. If the picture contains noise bars and it is not clear to see (tracking adjustment): If noise bars appear during normal playback or still playback, follow the Playback picture Playback picture. Recording Set the TV set to the video channel and insert a cassette into the VCR; make sure that the cassette's protection tab is still in. Select a channel to record from.
Select the AV channel if you are recording via the 21-pin scart cable. Press to start recording. External recording control The AV input of this VCR is equipped for future use with external equipment having external timer recording control such as digital satellite receivers.
Toyota Solara 99 Service Manual
The Aerial AV input can be set to EXT LINK 1 or EXT LINK 2 depending on the equipment to be connected. Timer recording The recording timer allows you to programme the recording time of TV PROG/CHECK programmes up to 1 month in advance. Use the on-screen menu to programme a maximum of 16 recordings.
Timer recording Press MENU, select and press ENTER Timer recording 1 / 3. Timer recording Quitting the timer mode TIMER Press TIMER; the video recorder symbol turns off. You can now play back a cassette or make a manual recording. Press TIMER again to reactivate the timer programme you entered previously. Displays the timer programmes for verification. (button on the unit only) TIMER CHECK Repeatedly press TIMER CHECK.
Timer recording Automatic SP/LP selection A: If, at the beginning of a timer programme, there is not enough tape left to complete it, the SP/LP function will automatically run the tape at LP speed. This ensures that the entire programme will be recorded. If the LP mode is not enough to 'stretch' the remaining tape to fit you will not be able to record all of the TV programme. INTELLIGENT TIMER This function makes it easier for you to time the recording of programmes I-TIMER transmitted by the same station at the same time but on different days. You can fully modify the programmes once they have been transferred to the Timer Recording menu.
VIDEO Plus+ Programming with the VIDEO Plus+ Function The VIDEO Plus+ Codes (numbers) make it easy to set the VCR for timer recording from TV channel and SAT channel. Video Plus+ The recording time may be slightly longer than the TV programme. 8 3 5 4 2 -Press the VIDEO Plus+.
VIDEO Plus+ If -appears under Pos after entering a VIDEO Plus+ Code (Number) Timer recording Pos is the Programme Position/TV Station Name. Date Start Stop Normally, the name of the TV station and the number of the programme position is displayed under Pos. VIDEO Plus+ VIDEO Plus+ Codes for Satellite Receivers /Cable TV This VCR is not designed to control (switch on or change channel) your satellite receiver or Cable TV box, however, it can be taught to recognise VIDEO Plus+ Codes for Satellite stations. The Satellite receiver or Cable TV box must be switched on and the correct station selected. Others Menu Others Tape length: AUTO( E-240) SQPB: AUTO: 4:3 VCR display: DIMMED EXT LINK Sets the tape length of the cassette you use. Tape length AUTO ( E - 240 ), E - 195, E - 260, E - 300: select: return: exit. Manual setup This VCR has 99 programme positions that can be tuned to receive TV stations.
In certain circumstances you may wish to tune in a station manually or rename a TV station. Manual Tuning Tuning Tuning Press MENU and select Pos Name Pos Name Ch Press.
Manual setup Changing the name of TV stations Tuning Press Menu and select Tuning Pos Name Pos Name Ch Press ENTER 1 BBC1 Manual Select and press ENTER 2 BBC2 7 -3 ITV 8 -Select a TV station 4 CH4. Manual setup Changing the order of TV stations or deleting a station Tuning Tuning Press MENU and select Pos Name Pos Name Ch Press ENTER 1 BBC1 Manual Select and press ENTER 7 -2 BBC2 3 ITV 8 -. Manual setup Restart Auto Setup Tuning Tuning Press MENU and select Manual Auto Setup Press ENTER Shipping condition Auto Select Setup and press ENTER Owner ID Press ENTER The Auto Setup menu will be displayed.: yes: no The Tuning will start automatically.
EXIT ENTER Note. Owner ID Tuning To change the Owner ID Manual Press MENU and select Tuning Auto Setup Press ENTER Shipping condition Select Owner ID and press ENTER Owner ID Use the Numeric buttons or to enter the current PIN number.
Ebl 99 Service Manual Pdf
After entering the correct PIN number, you can change the Name, House No and Postcode. Clock setting The clock will normally be set correctly during Auto-Setup however, in some circumstances the VCR cannot set the clock automatically. In this case, follow the operation steps below to manually set the clock. On Screen Display. To manually adjust the clock Menu Press MENU.
The settings for operating the TV with the remote control have already been made. No additional settings need to be performed. However, some of old Panasonic TVs cannot be operated using this remote control. TV-Stand-by/on Press to switch the TV from on to stand-by mode or vice versa.
Advanced functions Repeat Playback The video recorder repeats playback from beginning to end of a recording. In Stop or Playback mode, press the Playback button for longer than 5 seconds. The video recorder displays an 'R', indicating repeat play mode. Press to stop playing back at any time. Advanced functions Limiting the recording and playback time Switches the unit into stand-by mode after the set time of recording, playback or in Stop mode.
OFF TIMER Press OFF TIMER repeatedly to extend the switch-off time from 30 to 60, 120, 180 or 240 minutes. Advanced functions Convenient Automatic Functions VCR Auto Power On When you insert a video cassette, the VCR switches on automatically. Auto Playback Start When you insert a video cassette with a broken erasure prevention tab, playback starts automatically without pressing the Play button. Before requesting service I HAVE AN ON SCREEN MESSAGE. You have attempted to carry out a function, which is Please follow the instructions as given on the display. Not possible at this time. It may be that no tape is inserted and you have pressed Play, or that you.
Before requesting service THE PICTURE OF A RECORDED PROGRAMME IS DISTORTED OR MISSING. The aerial or connection is defective. Check connections and reconnect as necessary. No programme was recorded because the VCR is Re-tune the VCR. Not tuned correctly.
Ism marathi software free for windows 7 64 bit. Incorrect programme position was selected. Select correct channel. Tape Care Some do's and dont's on tape care. 1) Use a good quality branded tape, such as Panasonic. 2) Keep in the box supplied with the tape, or a video case, when not in use.
3) Try to use the whole tape when making recordings and avoid re-recording over the same section of the tape repeatedly as this will help prevent premature tape wear. Specifications NV-MV20EB/EBL Power supply 220-240 V AC, 50/60 Hz Power consumption in operation multifunctional remote control (VCR and Panasonic TV) / 21-pin Scart Socket Controls VCR direct controls (main functions) 11 13 15 17 19 Video heads (helical scanning system). RF cable 10,12,14 VIDEO plus+ This equipment complies with European conformity requirements, in accordance with the conditions of electromagnetic compatibility and product safety. This equipment complies with the requirements of protection class 2. Matsushita Electric Industrial Co., Ltd.
F06C03-0 RQTD0079-B.
Hi, we have a 2007 Dethleffs Advantage 6971. It's plugged in to the mains at home for long periods of time to run a small oil filled radiator during the winter months. Every time i switch on the LCD control panel above the habitation door it shows that there is X?amps being fed into the leisure batteries. The two leisure batteries fitted are 80AH & 110AH Gel. Is it possible that the AH rating for the two combined batteries could be set too high on the LCD control panel? & would this make the charger to run constantly?
Does anyone know how to switch off the charger? I've read the manual but can't figure it out, it seems to be assumed that if you're connected to the mains then you'll be charging your batteries.
Thanks in advance. Bryan Posted: 5 January 2008 9:40 AM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Location: Herefordshire - 2015 Rapido 640F LHD 2.3ltr 150bhp. I don't think your Dethleff's control panel should have any direct effect on how your motorhome's battery charger functions - or at least not in the way you seem to be suggesting. The battery charger should charge the leisure batteries at whatever amperage the charger can manage, using a regimen appropriate to the battery type ('gel' in your case) and the batteries' state of charge at the time. In simplistic terms, the charger will 'sense' the batteries' charge-state and deliver a charge ranging from high when the batteries have been heavily discharged, progressively throttling back so that little or no charge is provided when the batteries are well charged up.
It's quite possible that your battery charger does operate automatically whenever your motorhome is connected to a 230V power supply, but whether this really matters will depend on what the charger does when your batteries have reached a fully-charged condition. At that point, as long as the charger has reduced its charging process to approaching zero, then there should be no problem. If it continued to charge your batteries strongly and indefinitely, then your batteries would be in big trouble. As your batteries are, apparently, still working OK, then it's reasonable to assume the charger enters 'maintenance mode' when the batteries are fully charged. I've no practical experience of Electrobloc products.
The battery charger on my Hobby carries a big illuminated button ON/OFF button, so it's very plain whether or not it's operating. If there is nothing similar on your Electrobloc, then you may find that there's a circuit-breaker on the vehicle's 230V RCD unit that be switched off to prevent the charger operating but still leave functional the power outlets into which you plug your radiator.
Posted: 5 January 2008 11:23 AM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Treasured contributor Posts: 893 Location: West Yorks & Thailand-Hymer S 700 G. Hello Bryan On the Elektrobloc unit there should be a large switch with the German words - 'Batterie Trennschalter'. This is the battery cut off switch.Switch in the up position is 'EIN = ON', or in the down position is 'AUS = OFF'. In the off position it means that your entire 12v system will be disconnected.This just prevents the leisure batteries from slowly discharging when laid up for a long period of time. BUTTTT be warned that by doing this, it also switches off the safety/drainage valve for your hot water tank. So please drain down any water in your Trauma heater and any water in your pipes before switching off the battery. The other point is that if this is not done, there is another feature that comes in to play.
If the battery monitor recognises a reading of less than 11v in your leisure batteries it will switch off ALL the 12v appliances anyway. Also make sure that your charge setting is for GEL batteries and not normal batteries. There are more knowledgable people than I on this forum who I'm sure will offer further advice, which will be more useful than I've explained here. Thai Posted: 5 January 2008 3:16 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Location: East Sussex. Motorhome: Knaus Boxstar 600 Street. A little thing in the back of my mind says the two leisure batteries should be, as nearly as possible, a matched pair.
That would imply same age, same type, and same capacity. Since yours are of different capacities, I wonder if they are of the same age? If not, and one is getting 'tired', I think it may upset the charging regime for the pair.
Ebl 99 Service Manual Online
It might be worth checking the electrolyte level on both to be sure a weak battery isn't causing the other to be 'boiled', by a charger than can't adequately read their state. Posted: 6 January 2008 8:32 AM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Location: Herefordshire - 2015 Rapido 640F LHD 2.3ltr 150bhp. Brian K: Amongst the documentation for my Hobby is a small Exide Gel-battery leaflet (in German).
One page lists the various combinations that are permissible when batteries are connected in parallel or serially. Thanks for that, Derek. Very interesting.
I didn't get the Exide battery leaflet in my info pack, so the permissible combinations were an unknown, especially the mixing of gel and wet. I therefore responded with what I'm sure I've seen Clive say previously. However, I had read ' The two leisure batteries fitted are 80AH & 110AH Gel' as meaning one 80AH wet + 1110AH gel; rather than meaning both were gel type.
Mar 18, 2018 - Torrent Microsoft Project Professional 2013 French. Torrentz - Fast and convenient Torrents Search Engine. Microsoft Project Professional. Nov 15, 2012 - Download Microsoft Project Professional 2013 and Project Server 2013! Chinese (Simplified), Chinese (Traditional), Dutch, French, German,. Nov 2, 2012 - I have uploaded VL and RTM(Single ISO) on torrent which are being. Microsoft Project Professional 2013 VL 32. Or French MUI Pack?
Hence the suggestion to check the electrolyte - though 'both' is clearly inappropriate. I had therefore thought it likely the 80AH would have been the original fit wet battery, to which Esustrek had possibly added the 110Ah gel.
Edited by Brian Kirby 2008-01-06 4:55 PM Posted: 6 January 2008 6:48 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Location: Herefordshire - 2015 Rapido 640F LHD 2.3ltr 150bhp. Thanks for the responses & suggestions, & apologies for the delay in getting back to you all. Both leisure batteries are Gel type, the second battery being fitted at first registration of the vehicle & both are less than one year old.
I checked that the charger was on the appropriate GEL setting (it was). I checked & found a trip switch that isolates the lighting / fridge & charger unit & have switched this off.
When i checked the van yesterday the underseat storage in the front dinette (where the 2nd leisure battery is stored) was toasty warm, is this normal? The control panel gave the following readings: To the vehicle battery 13.4volts To the Leisure batteries 13.6volts +4.6amps 98% utilisable capacity Also on the leisure battery menu: 190AH Nominal capacity 152AH Utilisable capacity (which is 80% of the rating of the 2 batteries) The van has been hooked up to the mains for several weeks & would have thought that the +4.6amps being fed into the batteries after this length of time was excessive. I've scanned the instructions for the Schaudt DT 220 B control panel into a PDF file & uploaded it here It will be there for 7 days or 100 downloads, whichever comes first. Hopefully someone will be good enough to have a look at the manual & tell me if the settings i've quoted are OK Bryan Posted: 7 January 2008 2:51 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Forum master Posts: 3140 Location: New Milton. Thanks for the Download, I have added it to my catalogue of information. I do not understand why your system indicates such a significant charging current unless you have a constant electrical load on your leisure batteries which you are unaware of or they are very very leaky internally.
You need to be sure that no electrical loads are turned ON first. The Elektroblock uses a clever charging algorythm. Initially the charger will limit the charging current to a maximum number of amps so as not to damage itself. Initially the battery terminal voltage will rise as the battery charges. In the later phases of charge the charging current will automatically be reduced to stop excessive battery voltage. In the final phase of charging the current will be very small, even so the battery voltage will reach 14.3 volts as its maximum and the current continue to fall. The Elektroblock system will maintain this voltage for 8 hours (for a GEL battery) and then the limiting voltage set by the charger will automatically reduce to 13.8 volts.
For a while no charging current will flow but eventually the voltage will fall to 13.8 volts and the charger will then provide a small current to maintain this voltage. Your 4.6 amps charging current suggests that the charger is still on the first and main part of the charging cycle, your battery voltage also supports this. I suggest that you disconnect one at a time each leisure battery to be able to identify which one has the high internal leakage and hence is taking all this current. Yes the enclosure will be warm.
Singer 99 Service Manual
Its the cooling air for the electroblock. I hope there is a good natural airflow provided for it. Hope that helps.
Clive Posted: 7 January 2008 5:44 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Pops in from time to time Posts: 81 Location: Motorhome = 2007 Dethleffs Advantage A 6971 SG. Thanks for the Download, I have added it to my catalogue of information. Kenny bernstein mac tool box for sale.
You're welcome Clive B.T.W. It was the second leisure battery getting hot, not the Elektroblock unit. As far as i'm aware there is nothing drawing power from the 12v system, i've just checked the control panel now that the charger has been switched off for 24hrs. Vehicle battery 12.8 volts Leisure batteries 12.7 volts - 0.1 amps 97% utilisable battery capacity I'll take your advice & try the batteries individually to see if this makes any difference. Bryan Posted: 18 January 2008 4:38 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Pops in from time to time Posts: 81 Location: Motorhome = 2007 Dethleffs Advantage A 6971 SG.
Update: I removed the 110Ah battery & left the original 80Ah battery on charge for 24hrs & all seems to be working OK, the control panel now gives a reading of +0.2amps. No need to test the battery that i removed.
It had spilled some of it's content, a fact that was not apparent until it was lifted out of the van, i guess that means it's dead. I also found out that my Dethleffs manual gives instructions for the EBL 99 when in actual fact the unit fitted is EBL 220, which is prolly why i couldn't find the battery isolation switch, there isn't one, battery isolation is controlled from the panel.
I emailed Dethleffs direct on Monday evening & received the correct manual in the post Thursday morning. I could scan to PDF if there's any interest, takes forever though.
Thanks to all who gave advice, it's very much appreciated & gives a little confidence to a newby like myself to take a look & check things out. Bryan Posted: 18 January 2008 6:39 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Location: East Sussex. Motorhome: Knaus Boxstar 600 Street. Hi Brian Yes have cleaned up & disposed of the battery at the local dump.
Fluke 99 Service Manual
Ebl 99 Service Manual Download
As for who owes me a new battery? It's not really something that i had thought about, i have two new batteries that i bought last year for our old van but ended up not using them. I will most likely remove the original battery & fit these as a pair. I could i suppose go back to the dealer who fitted the battery to the vehicle from new but to be perfectly honest, where possible, i would prefer to sort out any simple issues myself & pay someone who really knows what they're doing to sort out what i can't. Bryan Posted: 18 January 2008 7:52 PM Subject: RE: ELEKTROBLOCK EBL 99 CHARGER Forum master Posts: 3140 Location: New Milton.